Fibre optics
Connect distant buildings, yard poles and remote network closets, or find out why a fibre link keeps dropping. We pull, fusion-splice, terminate and OTDR-test single-mode and multimode fibre across the GTA.
- In business since 2020
- We walk the site before we quote
- Labelled, tested and documented at handover
What we can help with
Fibre carries a network further than copper can, and it doesn’t pick up electrical interference on a pole in an open truck yard. We pull, fusion-splice, terminate and OTDR-test single-mode and multimode fibre across the GTA and select Southern Ontario sites.
- A run longer than copper can carry, like a camera on a pole
- A fibre link that keeps dropping
- New fibre spliced, terminated and tested
Photos from our jobs
How it works
Finding faults in existing fibre
A loss test tells you a fibre is losing too much light. An OTDR tells you where. It sends pulses down the fibre and measures what comes back, so a break, a tight bend or a dirty connector shows up at a specific distance along the cable.
Backbones, splice trays and outdoor runs
We pull, fusion-splice and terminate fibre between main telecom rooms, remote wall cabinets and outdoor yard poles. Strands in scope are dressed in splice trays and landed on labelled patch panels, with loss results and OTDR traces supplied where specified.
- 1
- Launch
- Where the test set connects. The first spike is its own connector.
- 2
- Fusion splice
- A non-reflective loss event is shown as a step down. Splices and bends can produce similar features; interpretation depends on the test setup and comparison traces.
- 3
- Connector
- A reflective connection can show a spike and a loss step. Test results and inspection are needed to assess the connection.
- 4
- End of the fibre
- A last spike, then only noise. A break looks like this too, but short of where the run should end.
What’s included
| Part | What we do |
|---|---|
| Cable | Single-mode and multimode fibre for backbones, risers and runs between buildings |
| Splicing | Fusion splicing on site, protected in splice trays and enclosures |
| Termination | Connectors, patch panels and wall enclosures, every strand numbered and labelled |
| Testing | Loss testing and OTDR testing, with the traces and results handed over |
| Inspection | Connector end-face inspection and cleaning when tracking down links that drop |
| Multiplexing & GPON | CWDM/DWDM to carry more links on existing strands, and GPON or multi-unit fibre testing where specified |
| Pole cameras | Fibre out to pole cameras and remote cabinets, where copper won’t reach |
We test and label the work in our scope, show your team how to use it, and hand over the agreed records: cable test reports, as-builts and port schedules where they’re part of the job.
Request a quote